BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//SMARTGATE - ECPv6.16.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://smartgate.co.id
X-WR-CALDESC:Events for SMARTGATE
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Asia/Krasnoyarsk
BEGIN:STANDARD
TZOFFSETFROM:+0700
TZOFFSETTO:+0700
TZNAME:+07
DTSTART:20170101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20180319T080000
DTEND;TZID=Asia/Krasnoyarsk:20180322T170000
DTSTAMP:20260517T001147
CREATED:20180301T102958Z
LAST-MODIFIED:20180301T103045Z
UID:1772-1521446400-1521738000@smartgate.co.id
SUMMARY:POWER QUALITY; HARMONICS & VOLTAGE DIPS
DESCRIPTION:OVERVIEW\nThe course will discuss various types of disturbance on power networks\, including the concept of electromagnetic compatibility\, the causes and effects of harmonics\, voltage dip and fluctuations\, flicker and the effects of variable speed drives\, UPS and switched mode power supplies. Also\, power quality measurements and how the results can be interpreted\, as well as the kind of power quality mitigation and conditioning techniques that you can apply. \nOBJECTIVE\nThis training aims to improve the knowledge\, skills\, and personal competence in supporting the activities of the management and operation of electrical assets of an industry\, which is expected to contribute in ensuring and improving performance in achieving the target company. \nCONTENT \n\nOverview of Power Quality\n\nIntroduction to Power Quality\, Power disturbances: symptoms & causes\nThe cost of poor power quality\, Internal vs. external/utility sources of PQ\nPQ Standards: IEEE\, EN and IEC\, Power Quality tools and application\n\n\nVoltage Dips & Flicker\n\nLow voltage cause and effects\, System impedance\, CBEMA curves\nIsolating the source of disturbance\, Severity of voltage events\nImpact of voltage sags\, Flicker\, standard and measurement\n\n\nHarmonics\, Distortion\, Voltage Unbalance and Resonance\n\nHarmonics\, distortion and distorted waveform\nVoltage unbalance and its impacts on motor\nPowers\, Power factors and Power factor correction\nHarmonics resonance\, The resonance dilemma\nHarmonics and winding pitch of generator\n\n\nHarmonic Sources\, Sequence and Their Effects\n\nNon linier loads in industrial application\, Harmonics sequences\nEffect on electrical apparatus & measurements\n\n\nMitigations\n\nMitigation on source of power quality disturbance\nMitigation on supply side\nSample Calculation Cost of PQ disturbance\n\n\n\nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/power-quality-harmonics-voltage-dips-batch1/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20180319T080000
DTEND;TZID=Asia/Krasnoyarsk:20180322T170000
DTSTAMP:20260517T001147
CREATED:20180302T074311Z
LAST-MODIFIED:20180302T074311Z
UID:1823-1521446400-1521738000@smartgate.co.id
SUMMARY:TRANSFORMER CONDITION ASSESSMENT LEVEL 2
DESCRIPTION:OVERVIEW\nDalam sistem tenaga listrik terdapat 3 (tiga) kategori transformator: \n\nTransformator penaik tegangan generator yang ada di pusat listrik\, berfungsi menaikan tegangan generator menjadi tegangan transmisi.\nTransformator penurun tegangan di gardu induk yang berfungsi menurunkan tegangan transmisi menjadi tegangan distribusi tegangan menengah\nTransformator distribusi yang berfungsi menurunkan tegangan menengah menjadi tegangan rendah\n\nTransformator penurun tegangan di gardu induk keadaannya paling kritis karena: \n\nBerfungsi men‐stabilkan tegangan memakai on load tap changer\nOn load tap changer merupakan sumber pemburukan isolasi\nBerhadapan dengan saluran transmisi dan jaringan tegangan menengah distribusi yang banyak mengalami gangguan\n\nOBJECTIVE\nSetelah mengikuti pelatihan ini engineer dan teknisi mempunyai gambaran mengenai titik‐titik kritis yang ada di transformator sehingga tau langkah‐langkah operasi dan pemeliharaan yang perlu diambil agar transformator tidak mengalami kerusakan. \nCONTENT \n\nBagian‐bagian utama dari transformator:\n\nBushing\nClamp penyambung\nKondensor pada bushing\nMinyak bushing\nKumparan primer dan sekunder\nIsolasi kumparan\nPengukuran isolasi\nTangki transformator\n\n\nMinyak transformator\n\nSusunan kimia minyak transformator\nTegangan tembus\nDGA (Dissolve Gas Analysis)\nTes kimiawi\n\n\nProteksi transformator\n\nProteksi terhadap gangguan di luar transformator\n\nRelai arus lebih\nRelai arus hubung tanah\n\n\nProteksi terhadap gangguan di dalam transformator\n\nRelai diferensial\nRelai hubung tanah terbatas\n\n\n\n\nBuil‐in protection\n\nRelai bucholz\nRelai sudden pressure\nRelai suhu kumparan\nFire protection\nExplotion valve\n\n\n\nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/transformer-condition-assessment-level-2-batch1/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
END:VCALENDAR