BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//SMARTGATE - ECPv6.16.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:SMARTGATE
X-ORIGINAL-URL:https://smartgate.co.id
X-WR-CALDESC:Events for SMARTGATE
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Asia/Krasnoyarsk
BEGIN:STANDARD
TZOFFSETFROM:+0700
TZOFFSETTO:+0700
TZNAME:+07
DTSTART:20170101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20180502T080000
DTEND;TZID=Asia/Krasnoyarsk:20180504T170000
DTSTAMP:20260516T225642
CREATED:20180301T091937Z
LAST-MODIFIED:20180302T104433Z
UID:1736-1525248000-1525453200@smartgate.co.id
SUMMARY:FUNDAMENTALS OF HAZARDOUS AREA CLASSIFICATION IN ELECTRICAL
DESCRIPTION:OVERVIEW\nHazardous areas are the areas where there is or there may be explosive atmosphere that required special requirements at the time of construction\, installation\, and use of electrical appliances. \nAccording to The Petroleum Rules\, 1976 that an area is considered hazardous areas\, if there are hydrocarbons with a flash point < 650C\, or there is a concentration of inflammable vapors or gases at concentrations that could occur combustion. Additionally\, deemed hazardous area if the processing\, storage\, and blending hydrocarbons or inflammable vapors or gases with a temperature equal to or above the temperature of the flash point. \nOBJECTIVE \n\nIdentify the hazards (hazards) potential\, especially endangering human health and the environment\nIncreasing labor competencies recognized according to HSE international standards in oil and gas\nProvide a new experience for the participants about the dangers of electricity\, especially in explosive gas atmospheres according to international standards\nParticipants are able to understand a process or operation on a system systematically\, to then determine whether the irregularities may lead to incidents or accidents that are not desirable.\n\nCONTENT \n\nHazards\, Risks and Control Measures\nZones and Properties of Flammable Materials\n\nGas Zones\, Grouping and Ratings\nExplosive Limits and Temperature\nClassifications\nEquipment Protection Levels\n\n\nHazardous Protection Requirements\n\nATEX Directive 94/9/EC\nATEX and CE markings\nExplosion Protection methods\nIngress Protection\nEquipment Certification and Labelling\n\n\nExplosion Protection by Enclosure Type\n\nFlameproof Enclosure Protection (Ex d)\nIncreased Safety Protection (Ex e)\n\n\nExplosion Protection by Other Methods\n\nIntrinsic Safety Protection (Ex i)\nPressurized Apparatus Protection (Ex p)\nNon‐incendive Protection (Ex n)\nOil Immersed Protection (Ex o)\nPowder Filled Protection (Ex q)\nEncapsulated Protection (Ex m)\n\n\nDesign\, Selection and Installation of Ex. Equipment\n\nGeneral Considerations\nIncreased Safety Equipment\nCable Glands\nInspection of Installations\n\n\n\nPREREQUISITES \nParticipants should be undergraduate electric power engineer with 2 years experience in operation and maintenance.  But any experienced engineer who has the same level of knowladge and experiance are welcome. \nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/fundamentals-of-hazardous-area-classification-in-electrical-batch2/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20180502T080000
DTEND;TZID=Asia/Krasnoyarsk:20180504T170000
DTSTAMP:20260516T225642
CREATED:20180302T080251Z
LAST-MODIFIED:20180302T080251Z
UID:1837-1525248000-1525453200@smartgate.co.id
SUMMARY:TRANSFORMER PROTECTION
DESCRIPTION:OVERVIEW\nUntuk dapat menyalurkan energi listrik dalam jumlah besar dan menempuh jarak yang jauh diperlukan saluran tegangan tinggi. Di ujung-ujung saluran tegangan tinggi di dapat transformator yang berfungsi menaikan tegangan dan menurunkan tegangan. Kursus ini akan membahas masalah proteksi dari transformator penaik tegangan dan transformator penurun tegangan. Saluran tegangan tinggi yang menghubungkan 2 (Dua) transformator ini umumnya melalui daerah terbuka yang rawan samberan petir\, sehingga banyak mengalami gangguan. Sistem proteksi generator harus bisa melindungi transformator terhadap gangguan-gangguan ini agar tidak mengalami kerusakan. \nOBJECTIVE\nKursus ini bertujuan untuk memberi pembekalan kepada operator pusat listrik tempat trafo penaik tegangan dan juga operator gardu induk tempat trafo penurun tegangan memahami fungsi dari sistem proteksi transformator\, sehingga tahu langkah-langkah operasional yang harus dilakukan apabila terjadi gangguan yang menyebabkan sistem proteksi transformator bekerja. \nCONTENT \n\nKonstruksi dan fungsi transformator\nBagian-bagian utama dari transformator\nRangkaian pengganti dari transformator\nProteksi dari transformator\, meliputi:\n\nProteksi arus lebih\nProteksi terhadap arus gangguan hubung tanah\nProteksi diferensial\nProteksi hubung tanah terbatas\nProteksi suhu tinggi pada kumparan\nProteksi terhadap kenaikan tekanan mendadak (sudden pressure)\nProteksi terhadap adanya hubung singkat dalam kumparan (relay bucholz)\n\n\nOn load tap changer:\n\nFungsi dan prinsip kerja on load tap changer\nSistem kontrol dari on load tap changer\n\n\nAnalisa kerusakan transformator\n\nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/transformer-protection-batch2/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
END:VCALENDAR