BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//SMARTGATE - ECPv6.16.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://smartgate.co.id
X-WR-CALDESC:Events for SMARTGATE
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Asia/Krasnoyarsk
BEGIN:STANDARD
TZOFFSETFROM:+0700
TZOFFSETTO:+0700
TZNAME:+07
DTSTART:20170101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20180827T080000
DTEND;TZID=Asia/Krasnoyarsk:20180831T170000
DTSTAMP:20260516T135452
CREATED:20180302T073353Z
LAST-MODIFIED:20180302T073353Z
UID:1819-1535356800-1535734800@smartgate.co.id
SUMMARY:TRANSFORMER CONDITION ASSESSMENT LEVEL 1
DESCRIPTION:OVERVIEW\nTraining Dasar‐dasar Pengujian/Pemeliharaan Transformator Tenaga memberikan pengetahuan mengenai panduan dasar bagaimana cara menguji transformator tenaga. Pada training ini juga mengajak peserta untuk melihat dan atau mempraktekan langsung proses dasar pengujian transformator tenaga. \nMateri pembelajaran yang diberikan pada training Dasa‐dasar Pengujian/Pemeliharaan Transformator Tenaga ini merupakan standar materi yang sudah bisa di Uji Kompetensi‐kan. Sehingga jika peserta ingin memiliki Sertifikasi Kompetensi Kementrian DJK – ESDM\, peserta bisa mengikuti Uji Kompetensi yang telah SMARTGATE sediakan. \nOBJECTIVE\nSetelah menyelesaikan kursus ini\, peserta akan memiliki pemahaman yang komprehensif mengenai dasar‐dasar pengujian/pemeliharaan transformator tenaga sehingga dapat membantu peserta dalam melaksanakan pekerjaannya baik secara langsung maupun supervisi pekerjaan. \nCONTENT \n\nManajemen pemeliharaan\nTransformator tenaga\nMedia insulasi (minyak trafo)\nDissolve Gas Analysis (DGA)\n\nPraktek: Pengambilan contoh minyak untuk uji DGA dan BDV\n\n\nBreakdown voltage\, water content\, Dissipasi factor\nPengukuran tahanan isolasi\n\nPraktek: Pengukuran tahanan isolasi\n\n\nPengujian rele Janson\, Bucholz & Sudden Pressure\n\nPraktek: Pengujian rele Janson\, Bucholz & Sudden Pressure\n\n\nPengukuran tahanan DC dan Ratio\n\nPraktek: Pengukuran tahanan DC dan Ratio\n\n\nPengukuran tahanan pentanahan dan NGR\n\nPraktek: Pengukuran tahanan pentanahan dan NGR\n\n\nPengujian SFRA\n\nPraktek: Pengujian SFRA\n\n\nAnalisa hasil SFRA\nPemeliharaan FAN dan motor sirkulasi minyak\n\nPraktek: Pemeliharaan FAN dan motor sirkulasi minyak\n\n\nPengukuran tahanan kontak\n\nPraktek: Pengukuran tahanan kontak\n\n\nPengujian Tangen Delta dan bushing\n\nPraktek: Pengujian Tangen Delta dan bushing\n\n\n\nCERTIFICATION \n\nSertifikat kehadiran dari SMARTGATE\nSertifikat Kompetensi dari Kementrian DJK ESDM (jika pelatihan diikuti dengan Uji Kompetensi)
URL:https://smartgate.co.id/events/transformer-condition-assessment-level-1-batch2/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20180828T080000
DTEND;TZID=Asia/Krasnoyarsk:20180831T170000
DTSTAMP:20260516T135452
CREATED:20180301T084734Z
LAST-MODIFIED:20180302T103619Z
UID:1722-1535443200-1535734800@smartgate.co.id
SUMMARY:ELECTRICAL INSTALATION IN STEAM POWER STATION LEVEL 1
DESCRIPTION:OVERVIEW\nAt the current time and in the next five years it is anticipated the role of steam power stations\, coal burning plants\, will be still dominating in the electrical energy production in Indonesia (around 60%). Therefore\, training for personnel who operate the plants is essentials. \nOBJECTIVE\nThe training objective is to give knowledge for the personnel in steam power stations to be able to operate the electric Installation properly. It is necessary because the electric installation in a steam power stations is relatively complicated. \nCONTENT \n\nOverview of the operation in a steam power station\n\nSteam circuit and water circuit\nCoal burning circuit and exhaust gas\nMain power circuit from the generator to the system\n\n\nElectrical circuit of the generator\n\nConstruction and operation of a synchronous generator\nExcitation circuit and voltage regulation\nSynchronizing to the main system\nRegulating of real power and reactive power\nCooling system of the generator\n\n\nStep up transformer\n\nFunction of the step‐up transformer\nWinding connection of the step‐up transformer\nCircuit breaker of the step‐up transformer\n\n\nAuxiliary Transformer\n\nElectrical circuit of the auxiliary transformer\nLoad of the auxiliary transformer\nSystem protection for the load of the auxiliary transformer\n\n\nStartup transformer\n\nCapacity and function of the startup transformer\nProcedure for startup\n\n\nEssential motors\n\nMotor for cooling water pump\nMotor for condensate pump\nMotor for boiler feed pump\nMotor for coal pulverizer\nMotor for coal conveyor\nMotor for feeding coal burners\nMotor for forced draft fan\nMotor for induce (sedot) draft fan\n\n\nWater treatment plant\nElectric power circuit of the steam power station\nSwitchyard of the steam power station\nElectric Precipitator\nCathodic protection\nStartup procedure of a steam power station\nSystem control of a steam power station\nSystem protection of a steam power station\n\nPREREQUISITES \nParticipants should be undergraduate electric power engineer with 2 years experience in operation and maintenance.  But any experienced engineer who has the same level of knowladge and experiance are welcome. \nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/electrical-instalation-in-steam-power-station-level-1-batch2/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
END:VCALENDAR