BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//SMARTGATE - ECPv6.15.13.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:SMARTGATE
X-ORIGINAL-URL:https://smartgate.co.id
X-WR-CALDESC:Events for SMARTGATE
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Asia/Krasnoyarsk
BEGIN:STANDARD
TZOFFSETFROM:+0700
TZOFFSETTO:+0700
TZNAME:+07
DTSTART:20200101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20210517T080000
DTEND;TZID=Asia/Krasnoyarsk:20210521T170000
DTSTAMP:20260417T033706
CREATED:20180302T073422Z
LAST-MODIFIED:20210111T085558Z
UID:1820-1621238400-1621616400@smartgate.co.id
SUMMARY:TRANSFORMER CONDITION ASSESSMENT ANALYSIS (BATCH#2)
DESCRIPTION:OVERVIEW\nIn the electric power supply industry\, the role of power transformers has a strategic role. Compare to distribution transformers\, power transformers have a different operation condition because on power transformer there are on load tap changer (moving context) and power transformers operate at the end of high voltage transmision lines where lightning strokes hit frequently on transmission lines creating travelling waves which could enter power transformers and create damage. Therefore installing lightning arrester in front of power transformers is very essentials. \nOBJECTIVE\nOn completion of this course\, engineers an technicians will have a comprehensive understanding of the principles of transformer maintenance objective\, transformer insulation system\, capability of transformer against thermal and mechanical stress\, transformer monitoring technique for ON and OFF line operation. \nCONTENT \n\n\n\nBagian-bagian utama dari transformator:\n\nBushing\nClamp penyambung\nKondensor pada bushing\nMinyak bushing\nKumparan primer dan sekunder\nIsolasi kumparan\nPengukuran isolasi\nTangki transformator\n\n\nMinyak transformator\n\nSusunan kimia minyak transformator\nTegangan tembus\nDGA (Dissolve Gas Analysis)\nTes kimiawi\n\n\nProteksi transformator\n\nProteksi terhadap gangguan di luar transformator\n\nRelai arus lebih\nRelai arus hubung tanah\n\n\nProteksi terhadap gangguan di dalam transformator\n\nRelai diferensial\n\n\n\n\nBuil-in protection\n\nReali bucholz\nRelai sudden pressure\nRelai suhu kumparan\nFire protection\nExplotion valve\n\n\nThe role of power transformers\n\nConstruction and working principles\nMain parts of power transformers\nLosses in power transformers\nWeak points of power transformers\nTechnical specification of power transformers\nInsulation coordination\n\n\nThe objective of maintenance:\n\nDevelopment of maintenance methodes\nWhat is condition base maintenance\nOil transformer construction\n\n\nPaper/cellulose and insulating oil Properties:\n\nChemical\nDielectric strength\n\n\nMaximum loading of oil filled transformer:\n\nThe capability of transformer against non-sinusoidal load\nTransformer aging v/s winding temperature\n\n\nTransformer through fault (external short circuit fault)\nIEE guide for the interpretation of gases generated in oil-immersed transformer\nTransformer winding and core deformation derection utilizing SFRA technique\nOn-line monitoring:\n\nTransformer non-sinusoidal load measurement and interpretation\nTransformer overall temperature profile/thermal image and interpretation\nMoisture in oil measurement\n\n\nOff-line monitoring\n\nMeasurement of main winding and bushing insulation power factor dissipation\nWinding and core displacement measurement\n\n\nOperational problems\n\nOn load tap changer\nAutomatic voltage regulator\nRequirements for paralel operations\nProtection of transformers\n\n\nPraktek\n\n\n\n\n\n\nPREREQUISITES \nParticipants should be undergraduate electric power engineer with 2 years experience in operation and maintenance. \nBut any experienced engineer who has the same level of knowladge and experiance are welcome. \nCERTIFICATION \n\nSertifikat kehadiran dari SMARTGATE
URL:https://smartgate.co.id/events/transformer-condition-assessment-level-1-batch3/
LOCATION:TANGERANG/tbc\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20210517T080000
DTEND;TZID=Asia/Krasnoyarsk:20210521T170000
DTSTAMP:20260417T033706
CREATED:20190215T103226Z
LAST-MODIFIED:20210118T035820Z
UID:2064-1621238400-1621616400@smartgate.co.id
SUMMARY:GENERATOR\, MOTOR\, TRANSFOMER AND MV FEEDER PROTECTION (BATCH#2)
DESCRIPTION:OVERVIEW \nMemberi pengetahuan tentang fungsi dan prinsip kerja sistem proteksi dalam sistem tenaga listrik. \nOBJECTIVE \nSetelah mengiku ti Pelatihan ini Peserta: \n\nFaham untuk menganalisa sebab gangguan yg terjadi dalam sistem berdasar kerja sistem proteksi\nMampu menganalisa tingkat kegawatan gangguan yang terjadi berdasarkan analisa kerja sistem proteksi\n\n CONTENT \n\nlnstalasi Sistem Proteksi\n\nKonstruksi Relai\nProteksi serta prinsip kerjanya\nBatere dan cicuit breaker\nTrafo arus dan trafo tegangan\nMacam dan sebab gangguan\nProteksi dan aspek keselamatan kerja\nMenghitung arus hubung singkat 3 fasa  dan 1 fasa ke tanah\, teori komponen simetris\nMenghitung arus hubung singkat dalam sistem multi busbar(program etap)\nMenentukan Spesifikasi Cir cuit Breakar\nInstruktur Pribadi Kadarisman\n\n\nGenerator Protection\n\nFungsi dan konstruksi generator sinkron 3 fasa\nKonstruksi stator dan kumparan stator\nKonstruksi Rotor\nSirkit arus penguat dan circuit breaker sirkuit penguat beberta discharge resistor\nKurva kapabilitas generator\nPentanahan titik netral generator\nTransformator Step Up\nProteksi Generator:\n\nRelay Over CurrentR\nelay Groun Facult\nRelay Differential\nRelay hubung tanah terbatas\nRelay eksitasi rendah\nRelay daya balik\nRelay negatif sequence\nRelay Overflux\nRelay suhu kumparan stator\n\n\nKaitan sistem\nProteksi generator dengan sistem proteksi mesin penggerak\n\n\nProteksi Transformator\n\nFungsi dan konstruksi transformator\nBagian bagian transformator\nFungsi dan susunan minyak transfornator\nVector Group Transformator\nProteksi Transformator:\n\nRelay Over Current\nRelay Ground Fault\nRelay Differential\nRelay hubung tanah terbatas\nRelay suhu kumparan\nRelay Bucholz\nRelay Sudden Pressure\n\n\nOn Load Tap Changer and Line Drop Compensator\nDisolved Gas Analysis\n\n\nMV Feeder Protection\n\nFungsi dan Konstruksi MV Feeder:\n\nSaluran Udara\nKabel Tanah\n\n\nMacam dan se bab Gangguan\nPerhitungan Arus Gangguan:\n\nTiga fasa\nSatu fasa ke tanah\n\n\nPenyetelan Relay Over Current dan Relay Ground Fault\nMenyusun spesfikasi teknik circuit breaker\nPenggaruh Neutral Grounding Resistor\nPenggunaan Auto Recloser:\n\nSyarat Mekanik\nSyarat Listrik\nPenyetelan\n\n\n\n\nMotor Protection\n\nKonstruksi dan prinsip kerja motor induksi 3 fasa dan 1 fasa\nPengertian7 mengenai slip\nKarakteristik putaran terhadap slip\nMengatur putaran\nProteksi motor:\n\nRelay Over Current\nRelay Ground Fault\nRelay Termal\nSekering lebur proteksi hubung singkat\nRelay Diferensial\n\n\nKombinasi dengan Sistem Kontrol untuk Proteksi Motor dengan Beban tertentu:\n\nPenggerak pompa lumpur\nPenggerak sabuk (belt) transport  batu bara\nProteksi terhadap slip karena rel licin pada motor traksi arus searah\n\n\n\n\n\nCERTIFICATION \n\n Certificate of Attendance
URL:https://smartgate.co.id/events/generator-motor-transfomer-and-mv-feeder-protection/
LOCATION:TANGERANG/tbc\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
END:VCALENDAR