BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//SMARTGATE - ECPv6.15.13.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://smartgate.co.id
X-WR-CALDESC:Events for SMARTGATE
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Asia/Jakarta
BEGIN:STANDARD
TZOFFSETFROM:+0700
TZOFFSETTO:+0700
TZNAME:WIB
DTSTART:20200101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VTIMEZONE
TZID:Asia/Krasnoyarsk
BEGIN:STANDARD
TZOFFSETFROM:+0700
TZOFFSETTO:+0700
TZNAME:+07
DTSTART:20200101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Asia/Jakarta:20210920T080000
DTEND;TZID=Asia/Jakarta:20210924T170000
DTSTAMP:20260416T054749
CREATED:20190813T025254Z
LAST-MODIFIED:20210111T084536Z
UID:2322-1632124800-1632502800@smartgate.co.id
SUMMARY:TRANSFORMER CONDITION ASSESSMENT ANALYSIS (BATCH#3)
DESCRIPTION:OVERVIEW\nIn the electric power supply industry\, the role of power transformers has a strategic role. Compare to distribution transformers\, power transformers have a different operation condition because on power transformer there are on load tap changer (moving context) and power transformers operate at the end of high voltage transmision lines where lightning strokes hit frequently on transmission lines creating travelling waves which could enter power transformers and create damage. Therefore installing lightning arrester in front of power transformers is very essentials. \nOBJECTIVE\nOn completion of this course\, engineers an technicians will have a comprehensive understanding of the principles of transformer maintenance objective\, transformer insulation system\, capability of transformer against thermal and mechanical stress\, transformer monitoring technique for ON and OFF line operation. \nCONTENT \n\n\n\nBagian-bagian utama dari transformator:\n\nBushing\nClamp penyambung\nKondensor pada bushing\nMinyak bushing\nKumparan primer dan sekunder\nIsolasi kumparan\nPengukuran isolasi\nTangki transformator\n\n\nMinyak transformator\n\nSusunan kimia minyak transformator\nTegangan tembus\nDGA (Dissolve Gas Analysis)\nTes kimiawi\n\n\nProteksi transformator\n\nProteksi terhadap gangguan di luar transformator\n\nRelai arus lebih\nRelai arus hubung tanah\n\n\nProteksi terhadap gangguan di dalam transformator\n\nRelai diferensial\n\n\n\n\nBuil-in protection\n\nReali bucholz\nRelai sudden pressure\nRelai suhu kumparan\nFire protection\nExplotion valve\n\n\nThe role of power transformers\n\nConstruction and working principles\nMain parts of power transformers\nLosses in power transformers\nWeak points of power transformers\nTechnical specification of power transformers\nInsulation coordination\n\n\nThe objective of maintenance:\n\nDevelopment of maintenance methodes\nWhat is condition base maintenance\nOil transformer construction\n\n\nPaper/cellulose and insulating oil Properties:\n\nChemical\nDielectric strength\n\n\nMaximum loading of oil filled transformer:\n\nThe capability of transformer against non-sinusoidal load\nTransformer aging v/s winding temperature\n\n\nTransformer through fault (external short circuit fault)\nIEE guide for the interpretation of gases generated in oil-immersed transformer\nTransformer winding and core deformation derection utilizing SFRA technique\nOn-line monitoring:\n\nTransformer non-sinusoidal load measurement and interpretation\nTransformer overall temperature profile/thermal image and interpretation\nMoisture in oil measurement\n\n\nOff-line monitoring\n\nMeasurement of main winding and bushing insulation power factor dissipation\nWinding and core displacement measurement\n\n\nOperational problems\n\nOn load tap changer\nAutomatic voltage regulator\nRequirements for paralel operations\nProtection of transformers\n\n\nPraktek\n\n\n\n\n\n\nPREREQUISITES \nParticipants should be undergraduate electric power engineer with 2 years experience in operation and maintenance. \nBut any experienced engineer who has the same level of knowladge and experiance are welcome. \nCERTIFICATION \n\nSertifikat kehadiran dari SMARTGATE
URL:https://smartgate.co.id/events/transformer-condition-assessment-analysis-batch3/
LOCATION:TANGERANG/tbc\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20210921T080000
DTEND;TZID=Asia/Krasnoyarsk:20210924T170000
DTSTAMP:20260416T054749
CREATED:20180302T031713Z
LAST-MODIFIED:20210111T084640Z
UID:1799-1632211200-1632502800@smartgate.co.id
SUMMARY:SISTEM TATA UDARA HVAC (BATCH#3)
DESCRIPTION:OVERVIEW\nDengan berkembangnya gedung bertingkat di kota‐kota besar\, timbul masalah tata udara yang menyangkut pengaturan suhu udara dan kelembapan udara yang bersirkulasi di dalam gedung tersebut. Untuk melayani masalah ini diperlukan teknik pendinginan serta teknik mensirkulasikan udara yang akan dibahas dalam kursus ini. \nOBJECTIVE\nKursus ini akan memberikan pengetahuan kepada pengikut kursus untuk: \n\nMerencanakan system pendinginan yang diperlukan dalam gedung bertingkat\nMenghitung daya dan energi yang diperlukan untuk melaksanakan pendinginan tersebut\nMerencanakan system control bagi motor listrik penggerak mesin pendingin dikaitkan dengan suhu yang dikehendaki\n\nCONTENT\nKonten kursus disusun dengan mengingat masalah‐masalah yang tersebut dalam over view dan objective: \n\nKebutuhan energi oleh manusia:\n\nUntuk klimatisasi:\n\nPendinginan/pemanasan\n\n\nUntuk transport\nUntuk iluminasi\nUntuk proses‐proses industry dan lainnya\n\n\nPrinsip kerja mesin pendingin\nSistem sirkulasi udara pendingin dalam gedung bertingkat\nSistem control motor penggerak mesin pendingin udara\nMenghitung daya dan energi untuk pendinginan gedung bertingkat\nPemeliharaan instalasi pendingin\nTeknik pemanasan\, mendistribusikan kalor pemanasan\nPasokan daya utama dan darurat\n\nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/sistem-tata-udara-hvac-batch3/
LOCATION:TANGERANG/tbc\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
END:VCALENDAR