BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//SMARTGATE - ECPv6.15.13.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:SMARTGATE
X-ORIGINAL-URL:https://smartgate.co.id
X-WR-CALDESC:Events for SMARTGATE
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Asia/Krasnoyarsk
BEGIN:STANDARD
TZOFFSETFROM:+0700
TZOFFSETTO:+0700
TZNAME:+07
DTSTART:20180101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VTIMEZONE
TZID:Asia/Jakarta
BEGIN:STANDARD
TZOFFSETFROM:+0700
TZOFFSETTO:+0700
TZNAME:WIB
DTSTART:20180101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20191001T080000
DTEND;TZID=Asia/Krasnoyarsk:20191004T170000
DTSTAMP:20260411T051224
CREATED:20190215T113235Z
LAST-MODIFIED:20190813T034548Z
UID:2066-1569916800-1570208400@smartgate.co.id
SUMMARY:CONTROL INSTRUMENTATION\, OPERATION AND MAINTENAMNCE (BATCH#3)
DESCRIPTION:OVERVIEW \n Training ini bertujuan untuk memberikan pengetahuan mengenai dasar-dasar sistem control yang ada di pusat listrik khususnya yang menyangkut control frekuensi dan tegangan. \nOBJECTIVE \n Setelah mengikuti training ini diharapkan peserta memahami bagaimana nilai frekwensi dan tegangan di pusat listrik di control dan bagaimana proses control yang terjadi di berbagai macam pusat listrik terutama pada PLTU dan PLTD: \nCONTENT \n\nGeneral control problem\n\nControl system\nProses control\nSet points\n\n\n\n\nControl instrument\n\nThermal sensors\nAnalog signal conditioning\nMechanical sensors\nOptical sensors\nDigital signal conditioning\n\n\nControl of sinkrones generators\n\nVoltage control\nFrekwensi control\nSynchronizing of generators\nControl of active power\nControl of reactive power\n\n\nGovernor\n\nConstruction and function\nCharacteristics\nPrimary control\nSecondary control\nLoad sharing between generators\n\n\nAutomatic voltage regulator\n\nExcitation system of synchronize generators\nContruction and function of automatic voltage regulators\nField discharge resistor\nCapability curve\nUnder excitation protection\n\n\nControl system in a steam power station\n\nMain steam valve controlled by governor\nThrottle governing\nNozle governing\nBoiler feed pump control\nCombustion system control\nCoal conveyor control\n\n\nMaintenance of valve\n\nMaintenance of steam valve\nMaintenance of water valve\nMaintenance of air valve\n\n\nThe maintenance of valve should also cover the maintenance of:\n\nIts driving mechanism\nIts automation system\nIts sealing system\nTesting the operation of safty valves referring to safety regulation\n\n\nVoltage control on medium voltage line\n\nOn Load tap Changer (OLTC) in ther substation\nConstruction and the function of OLTC\nThe role of automatic voltage regulator controlling the OLTC\nTher application of line drop compensator\nApplication of induction regulator as booster\nApplication of static VAR compensator as voltage stabiliser\n\n\nThe maintenance of valve should also cover the maintenance of:\n\nIts driving mechanism\nIts automation system\nIts sealing system and seats\nTesting the operation of safty valves referring to safety regulation\n\n\nVoltage control on medium voltage line\n\nOn Load tap Changer (OLTC) in the substation\nConstruction and the function of OLTC\nThe role of automatic voltage regulator controlling the OLTC\nThe application of line drop compensator\nApplication of induction regulator as booster\nApplication of static VAR compensator as voltage stabilise\n\n\n\nCERTIFICATION \n\n Certificate of Attendance
URL:https://smartgate.co.id/events/control-instrumentation-operation-and-maintenamnce/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20191007T080000
DTEND;TZID=Asia/Krasnoyarsk:20191011T170000
DTSTAMP:20260411T051224
CREATED:20180302T044514Z
LAST-MODIFIED:20190813T031226Z
UID:1807-1570435200-1570813200@smartgate.co.id
SUMMARY:STEAM POWER PLANT LEVEL 2 (BATCH#3)
DESCRIPTION:OVERVIEW\nThis training suits for someone who has experienced working in level 1 category of Steam Power Plant operation. The trainees will get understanding about Steam Power Plant main equipment operation such as boiler system \, turbine system and generator system. The trainees will learn the Steam Power Plant main equipment operation\, include the main equipment design and construction philosophy\, protective device equipment and operation parameter limits. \nOBJECTIVE\nOn completion of this training\, the trainees will have a comprehensive understanding of the main equipment and auxiliaries’ operation\, with a fully awareness to operating parameters limitation. By this training the trainees will more aware to each equipment function and parameters limitation relating to main equipment operation. This course will enhance the operator knowledge\, and suitable as preparation to the level 2 competency auditing programme. \nCONTENT\nBOILER OPERATION \n\nBoiler construction\n\nBoiler pressure part\nAir combustion and exhaust gas system\nFuel burning equipment\nBoiler control system\n\n\nFuel\, combustion air & boiler water\n\nFuel\nCombustion air\nBoiler water\n\n\nBoiler Operation\n\nStart‐up\, on load & shut down operating procedure\nKinds of attention during operation\nProtection equipment\, alarms and trips\nBoiler operating hazard\n\n\n\nTURBINE OPERATION \n\nTurbine working principle\n\nConversion heat energy to mechanical energy\nImpulse\, Reaction and Multistage steam turbine\n\n\nTurbine construction\n\nTurbine rotor and turbine stator\n\n\nTurbine Auxiliaries\n\nLube and hydraulic oil system\nGovernor system\nSealing & gland system\nTurbine protective device\n\n\nTurbine operation\n\nStart‐up preparation\nStart‐up\nSynchronize & loading\nStopping and standby\n\n\n\nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/steam-power-plant-level-2-batch2/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20191007T080000
DTEND;TZID=Asia/Krasnoyarsk:20191011T170000
DTSTAMP:20260411T051224
CREATED:20190215T102342Z
LAST-MODIFIED:20190813T034618Z
UID:2061-1570435200-1570813200@smartgate.co.id
SUMMARY:BASIC ELECTRIC MOTOR DIAGNOSTIC (BATCH#3)
DESCRIPTION:OVERVIEW \nMembekali pengikut kursus dengan technic mutakhir yang menyangkut operasi dan pemeliharaan motor listrik seperti metoda prediktif dan penggunaan software untuk diagnostik kondiso motor. \nOBJECTIVE \n Setelah mengikuti training ini peserta diharapkan mampu: \n\nMampu mengoperasikan motor-motor listrik yang menggunakan teknik mutakhir\nMampu melakukan pemeliharaan prediktif dan preventif berdasarkan analisa kondisi motor\nMampu menganalisa kerusakan motor\nMampu menggunakan software diagnostic untuk memperkirakan kondisi motor\n\nCONTENT \n Prinsip kerja dan macam motor listrik \n\n\n\nMotor induksi 3 fasa\nMotor induksi 1 fasa\nMotor arus searah\nMotor sinkron\n\n\nMasalah operasi motor listrik\n\nMasalah start\nKarakteristik torsi versus putaran\nPembebanan motor.\nPengaturan kecepatan motor\nButir diatas meliputi semua macam motor\n\n\nMotor Diagnistic\n\nMemantau kondisi motor yang beroperasi\nMenganalisa hasil pantauan\nMenentukan hasil pemeliharaan prediktif dan preventif\nMenganalisa (diagnosa) kerusakan motor\nAplikasi software diagnostic\n\n\nPenggunaan motor listrik di power station\n\n  \n CERTIFICATION \n Certificate of Attendance
URL:https://smartgate.co.id/events/basic-electric-motor-diagnostic/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20191010T080000
DTEND;TZID=Asia/Krasnoyarsk:20191010T080000
DTSTAMP:20260411T051224
CREATED:20180301T085612Z
LAST-MODIFIED:20190813T030805Z
UID:1728-1570694400-1570694400@smartgate.co.id
SUMMARY:ELECTRICAL PROBLEMS IN STEAM POWER STATION LEVEL 2 (BATCH#3)
DESCRIPTION:OVERVIEW\nThis course is dedicated for Electrical Engineers who will operate steam power stations\, particularly coal burning plants. Since electric energy production in Indonesia currently is dominated by coal burning plants (about 60%) and this domination will still exist in the next five years. From the view point of electrical engineering\, control and protection in coal burning plants is the most sophisticated problem among power plants. \nOBJECTIVE\nThis course is designed for Electrical Engineers who will operate steam power stations using coal as fuel. After following this course engineers hopefully will be able to operate a steam power stations from the electrical site which cover problems of operation\, maintenance and trouble shooting. \nCONTENT \n\nIntroduction\n\nOverview of electrical power systems\nThe role of steam power stations in electrical power system\nEnergy conversion in a coal burning station\n\n\nCoal handling Problem\n\nMotor control for coal conveyors\nMotor control for coal pulvirisers\nTypes of coal\n\n\nCombustion control\n\nControl of burners\nControl of induced draft fan\nControl of forced draft fan\nControl of air fuel ratio\n\n\nSteam control\n\nFunction of governor\nCharacteristic of governor\nControl of boiler feed pump\nPressure and temperature control of steam\n\n\nGenerator protection\n\nProtection scheme of a generator\nOver current protection\nGround fault protection\nDifferential protection\nRestricted earth fault protection\nReverse power protection\nUnder excitation protection\nRotor protection\nOver speed and over voltage protectionProtection against mechanical faults\nIntegration of generator\, turbine and boiler protection\n\n\nControl of efficiency\n\nHeat balance\nHeat rate\nEnergy for auxiliaries\n\n\n\nPREREQUISITES \nParticipants should be undergraduate electric power engineer with 2 years experience in operation and maintenance.  But any experienced engineer who has the same level of knowladge and experiance are welcome. \nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/electrical-problems-in-steam-power-station-level-2-batch3/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Jakarta:20191014T080000
DTEND;TZID=Asia/Jakarta:20191017T170000
DTSTAMP:20260411T051224
CREATED:20190813T032832Z
LAST-MODIFIED:20190813T032832Z
UID:2412-1571040000-1571331600@smartgate.co.id
SUMMARY:ELECTRICAL INSTALLATION IN STEAM POWER STATIONS (BATCH#3)
DESCRIPTION:OVERVIEW\nAt the current time and in the next five years it is anticipated the role of steam power stations\, coal burning plants\, will be still dominating in the electrical energy production in Indonesia (around 60%). Therefore\, training for personnel who operate the plants is essentials. \nOBJECTIVE\nThe training objective is to give knowledge for the personnel in steam power stations to be able to operate the electric Installation properly. It is necessary because the electric installation in a steam power stations is relatively complicated. \nCONTENT \n\nOverview of the operation in a steam power station\n\nSteam circuit and water circuit\nCoal burning circuit and exhaust gas\nMain power circuit from the generator to the system\n\n\nElectrical circuit of the generator\n\nConstruction and operation of a synchronous generator\nExcitation circuit and voltage regulation\nSynchronizing to the main system\nRegulating of real power and reactive power\nCooling system of the generator\n\n\nStep up transformer\n\nFunction of the step‐up transformer\nWinding connection of the step‐up transformer\nCircuit breaker of the step‐up transformer\n\n\nAuxiliary Transformer\n\nElectrical circuit of the auxiliary transformer\nLoad of the auxiliary transformer\nSystem protection for the load of the auxiliary transformer\n\n\nStartup transformer\n\nCapacity and function of the startup transformer\nProcedure for startup\n\n\nEssential motors\n\nMotor for cooling water pump\nMotor for condensate pump\nMotor for boiler feed pump\nMotor for coal pulverizer\nMotor for coal conveyor\nMotor for feeding coal burners\nMotor for forced draft fan\nMotor for induce (sedot) draft fan\n\n\nWater treatment plant\nElectric power circuit of the steam power station\nSwitchyard of the steam power station\nElectric Precipitator\nCathodic protection\nStartup procedure of a steam power station\nSystem control of a steam power station\nSystem protection of a steam power station\n\nPREREQUISITES \nParticipants should be undergraduate electric power engineer with 2 years experience in operation and maintenance.  But any experienced engineer who has the same level of knowladge and experiance are welcome. \nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/electrical-installation-in-steam-power-stations-batch3/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20191022T080000
DTEND;TZID=Asia/Krasnoyarsk:20191024T170000
DTSTAMP:20260411T051224
CREATED:20180301T092849Z
LAST-MODIFIED:20190813T030418Z
UID:1742-1571731200-1571936400@smartgate.co.id
SUMMARY:GENERATOR PROTECTION (BATCH#3)
DESCRIPTION:OVERVIEW\nGenerator adalah sumber energi listrik dalam sistem tenaga listrik. Dalam kursus ini pembahasan dibatasi pada generator arus bolak balik sinkron 3 (tiga) fasa\, mengingat bahwa generator merupakan sumber energi listrik maka harus dijaga agar generator sedapat mungkin tidak mengalami gangguan apalagi mengalami kerusakan. Oleh karenanya generator harus dilengkapi dengan sistem proteksi yang memadai. \nOBJECTIVE\nTujuan dari kursus ini adalah membekali operator pusat listrik dimana terdapat generator untuk memahami fungsi alat‐alat proteksi yang melindungi generator. Sehingga apabila terjadi gangguan yang menyebabkan sistem proteksi bekerja operator dapat mengetahui langkah‐langkah apa yang harus dilakukan. \nCONTENT \n\nKonstruksi dan prinsip kerja generator sinkron 3 fasa\nKumparan stator\nKumparan rotor\nMesin penggerak generator\n Mengatur operasi generator:\n\nMengatur nilai tegangan keluar (output)\nMengatur nilai frekuensi\nMelakukan sinkronisasi\nMengatur daya aktif\nMengatur daya reaktif\n\n\nKurva kapabilitas generator\nKarakteristik hubungan singkat generator\nProteksi generasi sinkron:\n\nProteksi terhadap arus lebih\nProteksi terhadap gangguan hubung tanah\nProteksi terhadap diferensial\nProteksi terhadap gangguan hubung tanah terbatas\nProteksi terhadap gaya balik\nProteksi terhadap eksitasi rendah\nProteksi terhadap gangguan hubung tanah di rotor\nProteksi terhadap suhu stator dan suhu bantalan\nProteksi yang berkaitan dengan gangguan mesin penggerak\n\n\nKaitan proteksi generator dengan sistem kontrol mesin penggerak\n\n  \nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/generator-protection-batch3/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
END:VCALENDAR