BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//SMARTGATE - ECPv6.15.13.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:SMARTGATE
X-ORIGINAL-URL:https://smartgate.co.id
X-WR-CALDESC:Events for SMARTGATE
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Asia/Krasnoyarsk
BEGIN:STANDARD
TZOFFSETFROM:+0700
TZOFFSETTO:+0700
TZNAME:+07
DTSTART:20180101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VTIMEZONE
TZID:Asia/Jakarta
BEGIN:STANDARD
TZOFFSETFROM:+0700
TZOFFSETTO:+0700
TZNAME:WIB
DTSTART:20180101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Asia/Krasnoyarsk:20191203T080000
DTEND;TZID=Asia/Krasnoyarsk:20191205T170000
DTSTAMP:20260411T051223
CREATED:20180302T025033Z
LAST-MODIFIED:20190813T030320Z
UID:1787-1575360000-1575565200@smartgate.co.id
SUMMARY:POWER SYSTEM ANALYSIS (BATCH#3)
DESCRIPTION:OVERVIEW\nTo give an overview and refreshment for electrical engineers about main problems in electric power systems\, about technical specifications of equipment and fault analysis. This course should be followed by electric power engineers who has an experience in the field of electric power system. \nOBJECTIVE\nTo give awareness for electric power engineers about subjects which should be considered when designing electric power system and the operation as well. \nCONTENT \n\nReview of power system components\nLoad flow analysis\nSymmetrical components\nCurrent transformer\, potential transformer\nSystem grounding\, principle of system protection coordination\nShort circuit analysis:\n\nThree phase fault\nSingle line to ground fault\n\n\nFault level and circuit breaker specification\nRelay adjustments related to fault level\n\nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/power-system-analysis-batch3/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Asia/Jakarta:20191210T080000
DTEND;TZID=Asia/Jakarta:20191212T170000
DTSTAMP:20260411T051223
CREATED:20190813T023635Z
LAST-MODIFIED:20190813T023849Z
UID:2298-1575964800-1576170000@smartgate.co.id
SUMMARY:FUNDAMENTALS OF HAZARDOUS AREA CLASSIFICATION IN ELECTRICAL (BATCH#3)
DESCRIPTION:OVERVIEW\nHazardous areas are the areas where there is or there may be explosive atmosphere that required special requirements at the time of construction\, installation\, and use of electrical appliances. \nAccording to The Petroleum Rules\, 1976 that an area is considered hazardous areas\, if there are hydrocarbons with a flash point < 650C\, or there is a concentration of inflammable vapors or gases at concentrations that could occur combustion. Additionally\, deemed hazardous area if the processing\, storage\, and blending hydrocarbons or inflammable vapors or gases with a temperature equal to or above the temperature of the flash point. \nOBJECTIVE \n\nIdentify the hazards (hazards) potential\, especially endangering human health and the environment\nIncreasing labor competencies recognized according to HSE international standards in oil and gas\nProvide a new experience for the participants about the dangers of electricity\, especially in explosive gas atmospheres according to international standards\nParticipants are able to understand a process or operation on a system systematically\, to then determine whether the irregularities may lead to incidents or accidents that are not desirable.\n\nCONTENT \n\nHazards\, Risks and Control Measures\nZones and Properties of Flammable Materials\n\nGas Zones\, Grouping and Ratings\nExplosive Limits and Temperature\nClassifications\nEquipment Protection Levels\n\n\nHazardous Protection Requirements\n\nATEX Directive 94/9/EC\nATEX and CE markings\nExplosion Protection methods\nIngress Protection\nEquipment Certification and Labelling\n\n\nExplosion Protection by Enclosure Type\n\nFlameproof Enclosure Protection (Ex d)\nIncreased Safety Protection (Ex e)\n\n\nExplosion Protection by Other Methods\n\nIntrinsic Safety Protection (Ex i)\nPressurized Apparatus Protection (Ex p)\nNon‐incendive Protection (Ex n)\nOil Immersed Protection (Ex o)\nPowder Filled Protection (Ex q)\nEncapsulated Protection (Ex m)\n\n\nDesign\, Selection and Installation of Ex. Equipment\n\nGeneral Considerations\nIncreased Safety Equipment\nCable Glands\nInspection of Installations\n\n\n\n  \nCERTIFICATION \n\nCertificate of Attendance (Public Training)
URL:https://smartgate.co.id/events/fundamentals-of-hazardous-area-classification-in-electrical-batch3-2/
LOCATION:JAKARTA / TBC\, JAKARTA\, Indonesia
CATEGORIES:CERTIFICATION,COURSES,EVENTS,SERVICES
ORGANIZER;CN="SMARTGATE":MAILTO:info@smartgate.co.id
END:VEVENT
END:VCALENDAR